TRYSIL 1022AL is a complete 300 cm lighting pole with two arms, each ending in a linear LED head. The body is extruded aluminium profile powder coated in RAL 9006, and the covers are clear, UV-stabilised polycarbonate. Both LED modules and the driver are already fitted, so no separate luminaires are ordered for it.
Height, arm span and weight
The pole stands 300 cm tall, the arms span 118 cm and the body is 24 cm wide. Norlys computed the photometry for a 3 m mounting height, so the LDT and IES files describe this pole exactly, not the same head hung lower or higher.
Net weight is 23.3 kg and the packed weight 26 kg. A pole of this height is not driven into the ground: it is set on a ground anchor or a concreting anchor, and both are ordered separately.
How much light it gives and where it sends it
The luminaire emits 3194 lm while drawing 23.3 W, which is 137.1 lm/W measured across the whole fitting, after the lens and the cover rather than at the bare diodes. At 3000 K the light is warm and yellowish, closer to an incandescent bulb than to neutral white.
The distribution comes from a Ledil SCL lens with an IESNA type II/III characteristic: an asymmetric beam stretched along a path instead of a circle around the pole. Upward waste is 0.9% of the flux (ULOR) and colour rendering is CRI 70.
DALI2 and NightDim control
Both heads support DALI2 together with the NightDim function. DALI needs its own control bus and a gateway, so on an ordinary phase dimmer this pole will not dim. The driver leaves the factory programmed for the maximum permitted current, and the remaining parameters are agreed with Norlys.
Installation, wiring and operating conditions
The ground anchor (index 180), the concreting anchor (3091) and the mounting adapter (1259) are accessories sold separately and are not part of the pole. The terminal block takes conductors up to 5x4 mm2, loop-through wiring up to 5x2.5 mm2, and the gland a round cable up to 13.6 mm in diameter.
The housing is rated IP65 and IK10, and the manufacturer specifies operation from -20 to +45 degrees C. Surge protection is 6/10 kV. The LED modules and the control gear are replaced by a qualified installer, so an electronics failure does not mean replacing the whole pole. The luminaire is class I and requires a protective earth conductor.
Add your comment about Lighting Pole TRYSIL 1022AL Silver LED 3000K DALI2 Norlys