NORLYS Astrid 2227CS is an 85 cm LED garden bollard with vertical ribs running along its body. Its Corten-coloured finish is powder-coated aluminium, not a body made from weathering steel. A milky PMMA diffuser sits behind the ribs in the upper section, keeping the illuminated area within the same continuous outline.
Light beside paths and terraces
The integrated LED produces warm white light at 2700 K. Output from the complete luminaire is 334 lm; the LED module itself is rated at 2112 lm. These figures describe different stages of the lighting system, so use the luminaire output when comparing the light that actually leaves the fitting. Diffuse distribution and the low bollard format suit garden paths, terrace edges and approaches from a driveway. Spacing should follow the layout and required lighting level rather than a fixed distance assumed to work in every garden.
The body measures 14 × 14 cm across. Check this footprint and the 85 cm height against the intended position and the location of the prepared electrical connection. Repeated vertical ribs and a simple outline work with modern, minimalist and Scandinavian landscaping. The brown finish remains a visible part of the design during the day, even when the light is switched off.
Dimming and LED servicing
Total luminaire consumption is 14.6 W, while the LED module is rated at 11.5 W. Astrid supports TRIAC phase dimming with leading-edge or trailing-edge control, so the selected control must suit that method. This is not an E27 bulb fitting. The installation manual identifies both the LED light source and control gear as replaceable by a professional, rather than as components for routine user replacement.
Preparing a fixed installation
The 220–240 V mains connection is Class I and requires a protective earth. Three 9 mm fixing holes are arranged at 120° intervals on a 65 mm circle. Mounting screws are not included. Anchors and adapters are selected for the installation surface and purchased separately. IP65 protection and IK10 impact resistance are confirmed specifications. Installation and servicing should be carried out by an appropriately qualified person.