Borg Pro 6153GR is a NORLYS post-top luminaire: a round, disc-shaped head that slips onto the top of a pole and is sold without the pole. It measures 51.2 cm across and 15.4 cm high. The body is powder-coated cast aluminium in graphite RAL 7016, closed underneath by a clear PMMA diffuser, and a silicone gasket seals the interior.
Mounting and what you need to buy separately
The sleeve fits a pole spigot 60 mm in diameter and slides 95 mm onto it. The pole, the reducer 3070XX0009 and the mounting adapter 154XX0010 are sold separately. A six-core, 6 m H05RN-F 6G1 cable leaves the luminaire for connection in a junction box inside the pole.
The head weighs 4.92 kg and has a lateral surface of 0.042 m² — both figures are needed when choosing a pole for the weight and the wind load. It is protection class I, so it needs the protective earth conductor, rated IP65 — dust-tight and protected against water jets — and IK08 for impact resistance. The inrush current is 43 A for 260 µs, which limits how many luminaires can share one circuit breaker.
What light it gives
A Philips Fortimo FastFlex LED module with a DALI driver delivers 6730 lm from the luminaire at 53 W, which is 127 lm/W. 3000 K is warm white, and CRI 80 is standard colour rendering. The light is shaped by a Ledil VSM lens with an IESNA Type V distribution, symmetrical around the pole: the luminaire lights a circular area rather than a strip along a path. The BUG rating is B3-U2-G1, and the manufacturer gives the illuminance distribution for a 4 m mounting height. On request Norlys builds versions with a different flux or another RAL colour.
DALI-2 control
The driver supports DALI-2 and NightDim (4DIM). Dimming over DALI needs a DALI controller or system — an ordinary phase-cut dimmer cannot replace it. From the factory the driver is set to maximum current, and Norlys programs other parameters by arrangement with its sales department.
Service and lifetime
The LED module and the driver can be replaced, but only by a professional service. According to LM-80 measurement, after more than 100,000 h of operation the flux keeps at least 90% of its initial value (L90B10), and the driver is rated for 100,000 h. The operating range is -20 to +45 °C.