The KGP LV100W24CG2 DALI is a 24 V constant-voltage LED power supply rated for a maximum output of 100 W, intended for installations using DALI-2 control. Its long, narrow housing measures 350 × 30 × 18 mm. Planning the mounting space therefore means allowing for the full length and cable connections, not just the low height.
Matching the LED load
This version supplies LED modules that require 24 V DC. The manufacturer specifies a load range of 30–100 W and an output current of 1.25–4.17 A. When choosing strips or modules, compare their voltage and combined power requirement. The 100 W rating is not a statement of brightness or the amount of light the finished installation will produce.
The rated input is 220–240 V AC. Constant-voltage operation distinguishes this driver from a constant-current supply: matching wattages alone does not make the two types interchangeable. Light colour and output depend on the connected LEDs rather than on the power supply itself.
DALI-2 and PUSH dimming
The driver supports DALI-2 and PUSH dimming through the DALI port. Its documented DALI dimming range is 1–100%. It suits a project where the control method is specified alongside the electrical supply. DALI-2 should not be taken as confirmation that any conventional wall dimmer will work with it.
Output wiring has a maximum permitted length of 3 m. Factor this into the distance between the driver and LED modules before completing the installation layout, rather than choosing a location solely because the housing fits there.
Housing and installation conditions
The slim body with covered connection areas is a technical installation component, not a decorative light fitting. The manufacturer specifies indoor use, electrical protection class II and IP20 protection. IP20 does not mean a dust-tight or water-protected enclosure, an important distinction when choosing its mounting position.
The datasheet confirms short-circuit, overcurrent, overvoltage and overtemperature protection. The warranty period is 5 years. Installation must also follow the documented temperature limits and wiring requirements, regardless of the profile or enclosure used for the connected lighting.