The Trysil 1067AL is a complete lighting column 300 cm high with a single arm that holds the luminaire 71 cm out from the shaft axis. Shaft and arm are extruded aluminium profile, powder-coated light grey RAL 9006, and the LED module sits behind clear UV-stabilised polycarbonate. The column stands on a square base plate 18 cm a side.
How much light it gives and what kind
The Philips Fortimo FastFlex LED module produces 1831 lm, and 1705 lm leaves the luminaire at a draw of 12.2 W — 139.8 lm/W for the whole fitting. 4000 K is neutral white, clearly cooler than a household bulb. Ra 70 is enough to see the surface and obstacles with confidence, but it does not render the colours of plants or facades faithfully.
A Ledil VSM lens gives an IESNA type V distribution: the light spreads symmetrically all around the column rather than in a narrow band along a road. The BUG rating B1-U1-G1 means little light escapes upward or sideways, which matters when the column stands near windows.
Control and service
The driver runs on DALI2 with NightDim, so the luminaire is dimmed from a DALI controller — an ordinary phase dimmer on the supply line changes nothing here. From the factory the driver is set to maximum current; Norlys programmes other levels and schedules by arrangement with its sales department.
The LED module and the driver are replaced by a professional service, and the manufacturer stocks service set ZS1091 for that. Module life is 100,000 h to L90B10, and the driver is also rated at 100,000 h.
Installation and what to buy separately
The column weighs 19.2 kg and ships in a 44 × 38 × 232 cm carton, so delivery needs room for a long package. No foundation parts are included: the mounting adapter (1259), the ground anchor (180) and the concrete-set anchor (3091) are ordered separately.
The terminals take conductors up to 5 × 4 mm², or up to 5 × 2.5 mm² when luminaires are looped through; the supply cable can be up to 13.6 mm in diameter. Protection class I requires an earth conductor in the circuit. The manufacturer allows 29 of these luminaires on one B16 breaker and 49 on a C16. IP65 protects against water jets from any direction, and IK10 is the highest impact resistance on the IK scale.
Where to put it
The column is assigned to parks, gardens, driveways and terraces — places where one light point has to light the area around itself. The form is modern: a straight rectangular profile turns at an angle into the arm, with no ornament.
Add your comment about Lighting column Norlys Trysil 1067AL light grey RAL 9006 LED 12.2 W 4000 K DALI2 300 cm